CTA8200 is a cost-effective digital-analog hybrid test system to test operational amplifiers, comparators, analog switches, power amplifiers, motor drives, Hall devices, three-terminal regulator, DC-DC power management, AC-DC power Manager, Li-ion battery protection circuit, radio circuits and other analog circuits.
Feature:
Windows XP/2000 operation system, C / C + + programme environment.
Debug user program source code through user self test program framework;
User programming structure with copy function, similar products can save a lot of time programming.
Mode selection list of available parameters to modify the test parameters and test conditions, no need to recompile the program, simplify the programming process.
Support parallel test and ping-pong test, and connect all the probe sets and handlers.
Test electrical source is software controlled, self-protection
Parameter description: ? PVM (Precision voltage meter)
Resolution 16BIT
? PVI (Dual-channel Power VI source)
1. Range:±50V / ±10A;
2.Force/Measurer voltage:1V,…,50V Auto-setting force/measure voltage in 6 ranges;Resolution:0.05%;
3. Force/Measurer current:200uA,…,10A Auto-setting force/measure current in 15 ranges;Resolution:0.1%;
4. Clamp V/I
? DVI (Dual-channel VI source)
1. Range:±50V / ±2A;
2.Force/Measurer voltage:1V,…,50V Auto-setting force/measure voltage in 6 ranges;Resolution:0.05%;
3. Force/Measurer current:200nA,…,2A Auto-setting force/measure current in 15 ranges;Resolution:0.1%;
4. Clamp V/I
? QVI (Quad-channel VI source)
1. Range:±20V / ±200mA;
2.Force/Measurer voltage:1V,…,20V Auto-setting force/measure voltage in 4 ranges;Resolution:0.05%;
3. Force/Measurer current:20nA,…,200mA Auto-setting force/measure current in 8 ranges;
Resolution:0.1%;
4. Clamp V/I
? OVS (Octal-channel V source)
1. Range:±20V / ±200mA;
2. Resolution:0.1%;
3. Clamp I.
? CBIT 64 (64-bit control bit unit)
1. Drive mode :OC;
2 .Drive voltage range :5-30V;
3. Drive current range :100mA;
4. The power to supply the relay:+5 V / +12 V;
5. The relays on the DUT board for the user :2×16
6. The relay driver pins to provide user:2×32
? QTMU (Quad time-measure unit)
1. High input voltage range: ± 50V;
2. Measurement resolution:10nS ± 0.1%;
? DACM (AC source and dual-channel measurement)
1. Audio Signal Virtual value:4V
2. AC output frequency range::8HZ-90KHZ
3. AC measurement accuracy :± 0.2%
4. AC measurement voltage range :± 10V
5. AC sine-wave measurement of center frequency :1KHZ
? HKV (High-voltage VI source)
1. Range:1000V/50mA;
2.Force/Measurer voltage: Auto-setting force/measure voltage in 2 ranges;
Resolution:0.05%;
3. Force/Measurer current:200nA,…,50mA Auto-setting force/measure current in 15 ranges;
Resolution:0.1%;
TRM (Special trimming module)
1. Channel number : 32 independent full-floating
2. Delay time:0-200MS
3. Voltage range :0-20V
4. Current range:0-2A
5. Accuracy of voltage control:0.1V
OVI (Octal -channel VI source)
1. Range:±50V / ±2A;
2. Force/Measurer voltage: Auto-setting force/measure voltage in 4 ranges ±20V,±10V,±5V,±2V ;
Force Resolution:0.15%(FS); Measurer Resolution:0.10%(FS);
3. Force/Measurer current: Auto-setting force/measure current in 5 ranges ±50mA,±5mA,±500uA,±50uA,±5uA ; Force Resolution:0.15%(FS); Measurer Resolution:0.20%(FS);Resolution:0.1%;
4. Clamp V/I
DIO (high-speed digital measurement module)
PIN count: 8/PCS
Test Rate: 20MHZ/5MHZ
Minimum pulse width: 10ns
Vector depth: 256k
Voltage range:-2.0-+7.0 v
Voltage accuracy of: 5MV
DRIVER: 2
COMPARATOR: 2
PMU functions: yes